CIFoundry
Back to Catalog
Hospital Medicine & Critical Care
FDA Cleared
Sepsis & deterioration early warning

eCART (Electronic Cardiac Arrest Risk Triage) Clinical Deterioration Suite

Save to shortlist
AgileMD, Inc.2016

Last reviewed Nov 11, 2026 against the sources listed on this page · How we review

At a glance

eCART is a gradient-boosted machine-learning early warning score developed at the University of Chicago that predicts in-hospital clinical deterioration (ICU transfer or death) using up to 97…

FDA:
510(k) K233253
Epic:
Not on record
Named users:
1 named in public reports
Published study:
Yes, linked below

Description

eCART is a gradient-boosted machine-learning early warning score developed at the University of Chicago that predicts in-hospital clinical deterioration (ICU transfer or death) using up to 97 real-time variables including vitals, labs, and nursing assessments. The eCARTv5 suite received FDA 510(k) clearance in June 2024 and has consistently outperformed NEWS, MEWS, and the Epic Deterioration Index in large multi-site studies.

clinical deteriorationearly warningmachine learningFDA 510(k) clearedsepsisICU transfer

Quick answers

Answered only from the sourced records on this page. Questions we can't answer from the record are left out. How we review

Is eCART (Electronic Cardiac Arrest Risk Triage) Clinical Deterioration Suite FDA cleared?
The public FDA database has one record that our team matched to eCART (Electronic Cardiac Arrest Risk Triage) Clinical Deterioration Suite. The most recent is 510(k) K233253 (eCARTv5 Clinical Deterioration Suite (“eCART”)), decided Jun 2024. Check that the cleared use matches how you plan to use it.FDA record K233253
Which health systems use eCART (Electronic Cardiac Arrest Risk Triage) Clinical Deterioration Suite?
Linked public reports name one organization: Yale New Haven Health. "Who's using this" below lists them all, plus any the maker reports. Ask the vendor for a reference at an organization like yours.Yale New Haven Health (Becker's Hospital Review)
Is there published research on eCART (Electronic Cardiac Arrest Risk Triage) Clinical Deterioration Suite?
Yes, this listing links a study (prospective / randomized study). Check whether the patients and setting in the study look like yours.Some authors of this study work for or have financial ties to the maker.Read the study
What are alternatives to eCART (Electronic Cardiac Arrest Risk Triage) Clinical Deterioration Suite?
We list 12 other tools of the same type (Sepsis & deterioration early warning). Shown here: 5, those with more on the public record first, then A–Z. Compare them on the same questions.COMPOSEREpic Deterioration Index (EDI)Epic Sepsis Model (ESM)Rothman IndexSepsis ImmunoScoreSee all 13

Security & contracting

The maker has not reported these details yet. Ask the vendor directly during evaluation.

Workflow stage
Not reported
Integrations
Not reported
Data inputs
Not reported
Deployment
Not reported
Signs a BAA
Not reported
SOC 2 report
Not reported
HITRUST
Not reported
Evidence type
Prospective / randomized study
Study authors
Include people who work for or have financial ties to the maker

Readiness details are self-reported by the maker and are not checked by Clinical Intelligence Foundry. Evidence type describes the kind of study or document the listing links to; it is not a rating or endorsement. Confirm compliance documents with the vendor before purchase.

Who's using this

3 organizations

Organizations named in public announcements or by the developer. Inclusion is not an endorsement.

Reported by the developer

University of Chicago Medicine250+ U.S. hospitals (AgileMD platform)

Last checked Nov 9, 2026. Spot an error? Let us know through the discussion below.

Get weekly updates for Hospital Medicine & Critical Care

Up to 5 new items a week: new tools, FDA decisions and studies. Newest first, never ranked. Confirm by email, unsubscribe any time.

Sources

This listing links to primary sources. Follow the links below to check details directly with the developer, regulator or publication.

Website GitHub Repository Research Paper

Some authors of this study work for or have financial ties to the maker.

FDA database records

  • K233253 · 510(k) · Jun 2024
    eCARTv5 Clinical Deterioration Suite (“eCART”)

Matched by our team from the public FDA database; checked Nov 10, 2026.

History (3)Show

Dated events on this listing's public record, newest first.

  1. Sep 13, 2026

    Added to CIFoundry

  2. Aug 19, 2025

    News report names Yale New Haven Health as a user (Becker's Hospital Review)source

  3. Jun 21, 2024

    FDA 510(k) K233253 decision datesource

[email protected]; 415-650-0522; 2261 Market Street #4378, San Francisco, CA 94114

Developer

AgileMD, Inc. (developed at University of Chicago by Dr. Dana Edelson and Dr. Matthew Churpek)

AgileMD, Inc.

Evaluating this tool?

Get a printable packet for your committee: what the public record shows, the gaps to raise with the vendor, and the questions for this kind of tool.

Prepare evaluation packet

Checklist for your role: Admin · Physician · IT · Compliance

Compare similar tools →

Own this tool?

Claim this listing to update its details and connect with your audience.